KENTEC-HOCHIKI UL/FM

eNET Elite RS Networking Communication Interface Card

* Up to 64 nodes.* High integrity protocol when wired Class A.* Fully secure against short or open circuit faults.* Simple 2-wire loop connection.* Supports open ended networks for retrofit applications.* Network wide test and disablement functions.* Network wide cause and effect logic.* Flexible co..

eView Analogue Addressable Repeater Panel - Red

* Up to 15 annunciators can be connected to each Elite or Elite RS fire control panel.* High brightness LED indications.* Internal sounder.* Replicates all panel controls (Elite RS)* Simple two-wire serial connection.* 24V DC powered.* Connection supervised by Elite RS fire control panel.* 1.2mm mil..

Hochiki 4 SENSOR BASE, BONE COLOR

* UL & ULC Listed.* Designed for use with all NS analog sensors.* Available in 4 and 6 inch models.* Contains a security locking tab for tamper protection...

Hochiki DUAL RELAY MODULE 2 AMPS

* Provides two independently configurable Form.* C relay contacts, using one SLC address.* UL 864 9th Edition Listed.* Uses the noise-immune Digital Communication.* Protocol (DCP), which utilizes interrupts for fast.* response to fires.* Up to 127 modules can be placed on a single. * SLC Loop.*..

Hochiki DUAL RELAY MODULE, 2 AMPS WITH ISOLATOR

* Provides two independently configurable Form C contacts per address.* Contacts are2A @ 30 VDC / 0.5A @ 120 VACC rated.* Up to127 devices can be used on each SLC loop.* Visible Bi-colored LED is software controlled and can be programmed to blink red or green when polled. The LED can be latched on w..

Hochiki Fast Response Contact Module

* UL 864 9th Edition Listed.* Single input contact monitor.* Fast, reliable contact monitoring utilizing the Hochiki DCP (Digital Communications Protocol)* 127 devices can be used per DCP loop.* Can be programmed to monitor Normally Open  (NO) or Normally Closed (NC) contacts.* Operates on Clas..

Hochiki Fixed temp/rate of rise heat sensor

* Low profile - only 2.00” high, including base.* Simple and reliable device addressing.* Automatic compensation for sensor contamination.* Uses the noise-immune Digital Communication Protocol.* (DCP), which utilizes interrupts for fast response to fires.* Two built-in power/alarm LEDs.* Programmabl..

Hochiki Hand Held Sensor Address Programmer

* Hand held address programmer designed to address the ESP range of Sensors and all other addressable devices such as wall sounders, mini-modules and manual call points.* Lightweight Design.* Quick And Reliable Addressing.* Over 8000 Address Settings From 1 Battery.* Displays Sensor Analog Value...

Hochiki Intelligent addressable manual pull station

* Single Action (Pull)* Addressable integrated design.* All metal construction.* Extremely easy to operate.* Bi-colored status LED indicates Standby and Alarm conditions.* Enclosed switch with glass rod (included)* Terminals accept up to 14AWG wire.* Surface mount back box available.* ADA compliant ..

Hochiki Photoelectric smoke sensor

* Low profile - only 2.00” high, including base.* Simple and reliable device addressing.* Automatic compensation for sensor contamination.* Built-in fire test feature.* Uses the noise-immune Digital Communication Protocol.* (DCP), which utilizes interrupts for fast response to fires.* Two built-in p..

Hochiki Pull Station Back Box

* Pull Station Back Box - 1-3/4" Deep.* Weatherproof Manual Pull Station.*  10 A, 120 VAC contacts.* Rugged die-cast aluminum housing.* Neoprene sealing gasket.* Corrosion-resistant construction.* Hex reset.* Latching pull-down lever.* Screw terminal connections...

Hochiki SENSOR BASE, BONE COLOR WITH ISOLATOR

* UL  Listed.* Ability  to  detect short circuit conditions Designed for use with all DCP analog sensor.* Built-in  LED indication upon short circuit condition.* Contains a security locking tab for tamper protection...

Hochiki SHORT CIRCUIT ISOLATOR

* Can be placed at any location on SLC loop* Checks the line for short circuit at power up. * If the line is normal, the relay will be returned on. If a line short is detected, the relay remains open* Indication of a single short circuit by a yellow LED..

Kentec Elite RS 1 Loop Analogue Addressable Fire Control Panel- Hochiki protocol - Red ,UL/FM® Approved

* One full SLC circuit up to 126 detector.* Access level 2 enable key-switch.* Can be networked with additional RS and/ or Elite control panels.* Compatible with eMatrix graphics annunciator.* 2 programmable sounder circuits.* 5 programmable inputs.* 3 programmable relays.* 24V-5.25A power supply.* ..

Kentec Elite RS 2 Loop Analogue Addressable Fire Control Panel- Hochiki protocol - Red ,UL/FM® Approved

* Two full SLC circuit up to 126 detector each.* Access level 2 enable key-switch.* Can be networked with additional RS and/ or Elite control panels.* Compatible with eMatrix graphics annunciator.* 2 programmable sounder circuits.* 5 programmable inputs.* 3 programmable relays.* 24V-5.25A power supp..

Taktis UL 2 loop card

The Dual Loop Panel Module monitors loop device status and provides status to the panel processor. It holds device configurations and operates in a standalone manner when catastrophic failures occur...

Taktis UL 2-16 Loop Hochiki protocol UL/FM® Approved

* Two full SLC circuit on board up to 126 detector.* Access level 2 enable key-switch.* 3 programmable inputs and 5 programmable.* Relay outputs.* 7 inch, full-color resistive touch screen.* 4 programmable NACs; Class B or 2 Class A with. * Internal synchronization.* 24V-10.25A power supply.* 1..

Taktis UL 2-16 Loop Hochiki protocol UL/FM® Approved With 48 Zones and Printer (TK903H1-14)

* Two full SLC circuit on board up to 126 detector.* access level 2 enable key-switch.* 3 programmable inputs and 5 programmable.* Relay outputs.* 7 inch, full-color resistive touch screen.* 4 programmable NACs; Class B or 2 Class A with.* Internal synchronization.* 24V-10.25A power supply.* 10,000 ..

Taktis UL 2-8 Loop Hochiki protocol UL/FM® Approved

* Two full SLC circuit on board up to 126 detector.* Access level 2 enable key-switch.* 3 programmable inputs and 5 programmable. * Relay outputs.* 7 inch, full-color resistive touch screen. * 4 programmable NACs; Class B or 2 Class A with. * Internal synchronization.* 24V-5.25A power..

Taktis UL network module (Ethernet and IFAM)

provides enhanced highspeed communication for networking fire control panels. The network provided by this module can support combinations of Taktis® Fire Alarm Control Panels and Taktis® Vision units. Taktis® Fire Alarm Control Panels can receive events from other panels in the network. The Class X..

Taktis UL Vision Network Repeater - surface - Red

* Full color 800 x 480 LCD with resistive touch screen and automatic backlight dimming.* 18 SWG.* 1.2mm mild sheet steel.* IP30 rated.* RS-485 two-wire. * Maximum distance from fire control panel: 3900 feet (1200meters)..